Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Heart Rhythm ; 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493989

RESUMO

BACKGROUND: Atrial high-rate episodes (AHREs) are frequent in patients with cardiac implantable electronic devices. A decrease in device-detected P-wave amplitude may be an indicator of periods of increased risk of AHRE. OBJECTIVE: The objective of this study was to assess the association between P-wave amplitude and AHRE incidence. METHODS: Remote monitoring data from 2579 patients with no history of atrial fibrillation (23% pacemakers and 77% implantable cardioverter-defibrillators, of which 40% provided cardiac resynchronization therapy) were used to calculate the mean P-wave amplitude during 1 month after implantation. The association with AHRE incidence according to 4 strata of daily burden duration (≥15 minutes, ≥6 hours, ≥24 hours, ≥7 days) was investigated by adjusting the hazard ratio with the CHA2DS2-VASc score. RESULTS: The adjusted hazard ratio for 1-mV lower mean P-wave amplitude during the first month increased from 1.10 (95% confidence interval [CI], 1.05-1.15; P < .001) to 1.18 (CI, 1.09-1.28; P < .001) with AHRE duration strata from ≥15 minutes to ≥7 days independent of the CHA2DS2-VASc score. Of 871 patients with AHREs, those with 1-month P-wave amplitude <2.45 mV had an adjusted hazard ratio of 1.51 (CI, 1.19-1.91; P = .001) for progression of AHREs from ≥15 minutes to ≥7 days compared with those with 1-month P-wave amplitude ≥2.45 mV. Device-detected P-wave amplitudes decreased linearly during the 1 year before the first AHRE by 7.3% (CI, 5.1%-9.5%; P < .001 vs patients without AHRE). CONCLUSION: Device-detected P-wave amplitudes <2.45 mV were associated with an increased risk of AHRE onset and progression to persistent forms of AHRE independent of the patient's risk profile.

2.
Int J Mol Sci ; 24(2)2023 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-36675028

RESUMO

Endothelial dysfunction (ED) causes worse prognoses in heart failure (HF) patients treated with cardiac resynchronization therapy (CRTd). ED triggers the downregulation of microRNA-130 (miR-130a-5p), which targets endothelin-1 (ET-1). Thus, we evaluated ED and the response to CRTd by assessing miR-130a-5p and ET-1 serum levels. We designed a prospective multi-center study with a 1-year follow-up to evaluate ED, ET-1, and miR-130a-5p in CRTd patients with ED (ED-CRTd) vs. patients without ED (NED-CRTd). Clinical outcomes were CRTd response, HF hospitalization, cardiac death, and all-cause death. At 1-year follow-up, NED-CRTd (n = 541) vs. ED-CRTd (n = 326) patients showed better clinical statuses, lower serum values of B type natriuretic peptide (BNP: 266.25 ± 10.8 vs. 297.43 ± 16.22 pg/mL; p < 0.05) and ET-1 (4.57 ± 0.17 vs. 5.41 ± 0.24 pmol/L; p < 0.05), and higher values of miR-130a-5p (0.51 ± 0.029 vs. 0.41 ± 0.034 A.U; p < 0.05). Compared with NED-CRTd patients, ED-CRTd patients were less likely to be CRTd responders (189 (58%) vs. 380 (70.2%); p < 0.05) and had higher rates of HF hospitalization (115 (35.3%) vs. 154 (28.5%); p < 0.05) and cardiac deaths (30 (9.2%) vs. 21 (3.9%); p < 0.05). Higher miR-130a-5p levels (HR 1.490, CI 95% [1.014−2.188]) significantly predicted CRTd response; the presence of hypertension (HR 0.818, CI 95% [0.669−0.999]), and displaying higher levels of ET-1 (HR 0.859, CI 98% [0.839−0.979]), lymphocytes (HR 0.820, CI 95% [0.758−0.987]), LVEF (HR 0.876, CI 95% [0.760−0.992]), and ED (HR 0.751, CI 95% [0.624−0.905]) predicted CRTd non-response. Higher serum miR-130a-5p levels (HR 0.332, CI 95% [0.347−0.804]) and use of ARNI (HR 0.319, CI 95% [0.310−0.572]) predicted lower risk of HF hospitalization, whereas hypertension (HR 1.818, CI 95% [1.720−2.907]), higher BNP levels (HR 1.210, CI 95% [1.000−1.401]), and presence of ED (HR 1.905, CI 95% [1.238−2.241]) predicted a higher risk of HF hospitalization. Hence, serum miR-130a-5p could identify different stages of ED and independently predict CRTd response, therefore representing a novel prognostic HF biomarker.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Hipertensão , MicroRNAs , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Estudos Prospectivos , MicroRNAs/genética , Insuficiência Cardíaca/genética , Insuficiência Cardíaca/terapia , Biomarcadores , Hipertensão/etiologia
3.
J Arrhythm ; 38(3): 439-445, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35785398

RESUMO

Background: The effects of lockdown on non-COVID patients are varied and unexpected. The aim is to evaluate the burden of cardiac arrhythmias during a lockdown period because of COVID-19 pandemics in a population implanted with cardiac defibrillators and followed by remote monitoring. Methods: In this retrospective, multicentre cohort study, we included 574 remotely monitored implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy-defibrillator (CRT-D) recipients implanted before January 1, 2019, at seven hospitals in the Campania region, comparing the burden of arrhythmias occurred during the lockdown period because of COVID-19 epidemics (from March 9 to May 1, 2020) with the arrhythmias burden of the corresponding period in 2019 (reference period). Data collection was performed through remote monitoring. Results: During the lockdown period, we observed ventricular tachyarrhythmias (ventricular tachycardia or fibrillation) in 25 (4.8%) patients while in seasonal reference period we documented ventricular tachyarrhythmias in 12 (2.3%) patients; the comparison between the periods is statistically significant (P < .04). Atrial arrhythmias were detected in 38 (8.2%) subjects during the lockdown period and in 24 (5.2%) during the reference period (P < .004). Conclusion: In seven hospitals in the Campania region, during the pandemic lockdown period, we observed a higher burden of arrhythmic events in ICD/CRT-D patients through device remote monitoring.

4.
Pharmacol Res ; 182: 106303, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35697289

RESUMO

OBJECTIVES: We evaluated whether Angiotensin receptor/Neprilysin inhibitors (ARNI) reduce heart failure (HF) hospitalizations and deaths in cardiac resynchronization therapy with defibrillator (CRTd) non-responders patients at 12 months of follow-up, modulating microRNAs (miRs) implied in adverse cardiac remodeling. BACKGROUND: adverse cardiac remodeling characterized by left ventricle ejection fraction (LVEF) reduction, left ventricular end-systolic volume (LVESv) increase, and the 6-minute walking test (6MWT) reduction are relevant pathological mechanisms in CRTd non-responders and could be linked to changes in miRNAs (miRs), regulating cardiac fibrosis, apoptosis, and hypertrophy. METHODS: miRs levels and clinical outcomes (LVEF, cardiac deaths, and 6MWT) were evaluated at baseline and one year of follow-up in CRTd non-responders divided into ARNI-users and Non-ARNI users. RESULTS: At baseline, there were no differences in levels of inflammatory markers, miR-18, miR-145, and miR-181 (p > 0.05) between Non-ARNI users (n 106) and ARNI-users (n 312). At one year of follow-up, ARNI-users vs. Non-ARNI users showed lowest inflammatory markers (p < 0.01) and miR-181 levels (p < 0.01) and higher values of miR-18 (p < 0.01)and miR-145 (p < 0.01). At one year of follow-up, ARNI-users had a higher increase of LVEF (p < 0.01) and 6MWT (p < 0.01) along with a more significant reduction of LVESv (p < 0.01) compared to Non-ARNI users. Cox regression analysis evidenced that ARNI-based therapies increase the probability of anti-remodeling effects of CRTd. Based on symptomatic improvements, echocardiographic and functional classification improvements, 37 (34.9%) patients among ARNI-users became responders, while only twenty (6.4%) patients became responders among Non-ARNi-users. CONCLUSIONS: ARNI might influence epigenetic mechanisms modulating miRs implicated in the adverse cardiac remodeling responses to CRTd.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , MicroRNAs , Antagonistas de Receptores de Angiotensina/uso terapêutico , Anti-Hipertensivos/uso terapêutico , Combinação de Medicamentos , Epigênese Genética , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/genética , Humanos , MicroRNAs/genética , MicroRNAs/uso terapêutico , Neprilisina/uso terapêutico , Receptores de Angiotensina/uso terapêutico , Volume Sistólico , Resultado do Tratamento , Remodelação Ventricular
5.
Metabolism ; 137: 155243, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35732222

RESUMO

BACKGROUND: In patients with type 2 diabetes mellitus (T2DM) the vaso-vagal syncope (VVS) recurrence could be due to the alteration of autonomic system function, evaluated by heart rate variability (HRV), and by 123I-metaiodobenzylguanidine (123I-mIBG) myocardial scintigraphy indexes: Heart to Mediastinum ratio (H/Mlate), and Washout rate (WR). The SGLT2-I could modulate/reduce autonomic dysfunction in T2DM patients with VVS. This effect could reduce the VVS recurrence in T2DM patients. METHODS: In a prospective multicenter study, after propensity score matching, we studied a population of 324 T2DM patients with VVS, divided into 161 SGLT2-I-users vs. 163 Non-SGLT2-I users. In these patients as SGLT2-I-users vs. Non-SGLT2-I users, we investigated the HRV and 123I-MIBG modifications and VVS recurrence at 12 months of follow-up. RESULTS: At follow-up end, the SGLT2-I-users vs. Non-SGLT2-I users had best glucose homeostasis and lower values of inflammatory markers, and resting heart rate (p < 0.05). The SGLT2-I-users vs. Non-SGLT2-I users evidenced the lowest low frequency/high frequency ratio (LF/HFr), a significant difference for all the indexes of autonomic dysfunction via ECG Holter analysis, and higher values of H/Mlate (p < 0.05). Finally, comparing SGLT2-I-users vs. Non-SGLT2-I users, we found a higher rate of VVS recurrence events, specifically of the vasodepressor VVS recurrence at 1-year follow-up (p < 0.05). We did not find a significant difference of mixed and cardio-inhibitory VVS recurrence events at 1 year of follow-up in the study cohorts (p > 0.05). At the Cox regression analysis H/Mlate (0.710, [0.481-0.985]), and SGLT2-I therapy (0.550, [0.324-0.934]) predicted all causes of syncope recurrence at 1 year of follow-up. CONCLUSIONS: Non-SGLT2-I users vs. SGLT2-I-users had alterations of the autonomic nervous system, with a higher rate of VVS recurrence at 1 year of follow-up. The indexes of cardiac denervation predicted the VVS recurrence, while the SGLT2-I reduced the risk of VVS recurrence. CLINICAL TRIAL REGISTRATION NUMBER: NCT03717207.


Assuntos
Diabetes Mellitus Tipo 2 , Cardiopatias , Inibidores do Transportador 2 de Sódio-Glicose , Síncope Vasovagal , Humanos , 3-Iodobenzilguanidina , Inibidores do Transportador 2 de Sódio-Glicose/uso terapêutico , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/tratamento farmacológico , Estudos Prospectivos , Sistema Nervoso Autônomo , Frequência Cardíaca/fisiologia , Síncope
6.
High Blood Press Cardiovasc Prev ; 28(6): 561-577, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34724167

RESUMO

Nowadays, there are robust clinical and pathophysiological evidence supporting the beneficial effects of physical activity on cardiovascular (CV) system. Thus, the physical activity is considered a key strategy for CV prevention. In fact, exercise training exerts favourable effects on all risk factors for CV diseases (i.e. essential hypertension, type 2 diabetes mellitus, hypercholesterolemia, obesity, metabolic syndrome, etc…). In addition, all training modalities such as the aerobic (continuous walking, jogging, cycling, etc.) or resistance exercise (weights), as well as the leisure-time physical activity (recreational walking, gardening, etc) prevent the development of the major CV risk factors, or delay the progression of target organ damage improving cardio-metabolic risk. Exercise training is also the core component of all cardiac rehabilitation programs that have demonstrated to improve the quality of life and to reduce morbidity in patients with CV diseases, mostly in patients with coronary artery diseases. Finally, it is still debated whether or not exercise training can influence the occurrence of atrial and ventricular arrhythmias. In this regard, there is some evidence that exercise training is protective predominantly for atrial arrhythmias, reducing the incidence of atrial fibrillation. In conclusion, the salutary effects evoked by physical acitvity are useful in primary and secondary CV prevention.


Assuntos
Doenças Cardiovasculares , Terapia por Exercício , Saúde Holística , Doenças Cardiovasculares/prevenção & controle , Humanos
7.
Clin Case Rep ; 9(8): e04477, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34457275

RESUMO

Permanent His bundle pacing is a physiological alternative to right ventricular pacing, resulting in a lower probability of pacing-induced cardiomyopathy and left ventricular ejection fraction deterioration. The combined use of UHD mapping systems allows precise and detailed information on the His bundle location, possibly providing more pacing option locations.

9.
Eur Heart J Digit Health ; 2(1): 171-174, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37155653

RESUMO

Aims: Following coronavirus disease (COVID-19) outbreak, the Italian government adopted strict rules of lockdown and social distancing. The aim of our study was to assess the admission rate for cardiac implantable electronic devices (CIEDs) replacement procedures in Campania, the 3rd-most-populous region of Italy, during COVID-19 lockdown. Methods and results: Data were sourced from 16 referral hospitals in Campania from 10 March to 4 May 2020 (lockdown period) and during the same period in 2019. We retrospectively evaluated consecutive patients hospitalized for CIEDs replacement procedures during the two observational periods. The number and type of CIEDs replacement procedures among patients followed by remote monitoring (RM), the admission rate, and the type of hospital admission between the two observational periods were compared. In total, 270 consecutive patients were hospitalized for CIEDs replacement procedures over the two observation periods. Overall CIEDs replacement procedures showed a reduction rate of 41.2% during COVID-19 lockdown. Patients were equally distributed for sex (P = 0.581), and both age [median 76 years (IQR: 68-83) vs. 79 years (IQR: 68-83); P = 0.497]. Cardiac implantable electronic devices replacement procedures in patients followed by RM significantly increased (IR: +211%; P < 0.001), mainly driven by the remarkable increase rate trend of both PM (IR: +475%; P < 0.001) and implantable cardiac defibrillator replacement procedures (IR: +67%, P = 0.01), during COVID-19 lockdown compared with 2019 timeframe. Conclusions: We showed a significant increase trend rate of replacement procedures among CIEDs patients followed by RM, suggesting the hypothesis of its increased use to closely monitoring and to optimize the hospital admission time during COVID-19 lockdown.

10.
Expert Rev Med Devices ; 17(11): 1207-1210, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33090884

RESUMO

Introduction: Following the coronavirus disease (COVID-19) outbreak, the Italian government adopted strict rules of lockdown and social distancing. The aim of our study was to assess admission rate for syncope leading to cardiac rhythm management (CRM) procedures in Campania, the third-most-populous region of Italy, during COVID-19 lockdown. Methods: Data were sourced from 14 referral hospitals in Campania from 10th March to 4 May 2020 (lockdown period) and during the same period in 2019. Among consecutive patients hospitalized for CRM procedures during the two observational periods, we retrospectively evaluated those admitted for arrhythmogenic syncope. Admission rate and the type of hospital admission between the two observational periods were compared. Results: Among 951 consecutive patients hospitalized for CRM procedures, 204 were admitted for arrhythmogenic syncope leading to CRM procedures. A significant increase in admission was shown in 2020 compared to 2019 (26.4% vs. 18.3%; P = 0.003). Moreover, regarding the type of admission to hospitals, attendance at the emergency department (ED) significantly increased (83.5% vs. 56.1%; P < 0.001); conversely, a significant decrease in urgent unplanned hospitalizations (6.2% vs. 35.5%; P < 0.001) was observed during COVID-19 lockdown. Conclusions: The hospitalization for arrhythmogenic syncope leading to CRM procedures increased during COVID-19 lockdown.


Assuntos
Arritmias Cardíacas/terapia , COVID-19 , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/etiologia , COVID-19/complicações , Controle de Doenças Transmissíveis , Serviço Hospitalar de Emergência , Hospitalização , Humanos , Itália/epidemiologia , Estudos Retrospectivos , SARS-CoV-2 , Síncope
11.
J Atr Fibrillation ; 12(6): 2361, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33024494

RESUMO

Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation. Yet tools and techniques used for confirmation of PVI vary greatly, and it is unclear whether the use of any particular combination of tools and techniques provides greater sensitivity for identifying gaps periprocedurally. It has been suggested the use of a high-density mapping catheter, which enables simultaneous recording of adjacent bipolar EGMs in two directions, may provide improved sensitivity for gap identification. Anonymized, acute procedural data was prospectively collected in AF ablation cases utilizing various workflows for confirmation of PVI. Post-hoc analysis was performed to evaluate the incidence of gaps detected by different diagnostic catheter technologies, including a high-density mapping catheter and circular mapping catheters (CMCs), and common techniques such as pacing the ablation lines. A total of 139 cases were included across three subgroup analyses: 99 cases were included in an indirect comparison of three mapping catheter technologies, revealing gaps in 36.7%, 38.9%, and 81.8% of cases utilizing a 10-pole CMC, 20-pole CMC, and a high-density mapping catheter, respectively; a direct comparison of diagnostic catheter technologies in 18 cryoballoon ablation cases revealed residual gaps in 22.2% of patients identified by high-density mapping which were missed previously with the use of a 3.3F CMC; in 22 cases utilizing a technique of pacing the ablation lines, high-density mapping identified residual gaps in 68.2% of patients. This proof of concept analysis demonstrated that the use of a high-density catheter which records orthogonal bipoles simultaneously, appears to improve acute detection of gaps in PVI lines relative to other commonly utilized techniques and technologies. The long-term impact of ablating these concealed gaps remains unclear. Further study, including direct comparison of diagnostic catheter technologies in a randomized setting with long-term followup, is warranted.

12.
J Cardiovasc Transl Res ; 13(6): 938-943, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32385806

RESUMO

Optimization of the atrioventricular (AV) and interventricular (VV) timings of the CRT is the most supposed correctable variable to improve the rate of CRT responder. The aim of the present study has been to evaluate if there is a specific subgroup of patients who can actually benefit the most from a hemodynamic optimization of AV. This is a prospective, observational single-center study that enrolled consecutive patients with clinical indication for CRT; all patients were implanted with CRT-D devices with SonR technology, able to automatically adjust AV and VV delay on a weekly basis. Among 57 patients, 39 (69%) showed a LVESV reduction > 15%. The SonR was able to modify the pacing parameters, but an increase of left atrial diameter was associated to a reduced AV variability, suggesting that an impaired left atrial function could potentially reduce the ability of the SonR algorithm to adjust the correct timing of pacing. Graphical abstract Patients with respectively a high (A) and low (B) AV timing variability, among several parameters that could potentially influence the AV timing, only left atrial dimensions demonstrated a significant impact. In fact an increase of left atrial diameter was associated to a reduced AV variability, suggesting that an impaired left atrial function could potentially reduce the ability of the SonR algorithm to adjust the correct timing of pacing.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Monitorização Hemodinâmica/instrumentação , Hemodinâmica , Potenciais de Ação , Idoso , Algoritmos , Função do Átrio Esquerdo , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
13.
J Med Case Rep ; 9: 289, 2015 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-26683613

RESUMO

INTRODUCTION: Results on the evolution of the clinical status of patients undergoing cardiac resynchronization therapy with a defibrillator after automatic optimization of their cardiac resynchronization therapy are scarce. We observed a rapid and important change in the clinical status of our non-responding patient following activation of a sensor capable of weekly atrioventricular and interventricular delays' optimization. CASE PRESENTATION: A 78-year-old Caucasian man presented with dilated cardiomyopathy, left bundle branch block, a left ventricular ejection fraction of 35 %, New York Heart Association class III/IV heart failure, and paroxysmal atrial fibrillation. Our patient was implanted with a cardiac resynchronization device with a defibrillator and the SonRtip atrial lead. Right ventricular and left ventricular leads were also implanted. Because of the recurrence of atrial fibrillation, the automatic optimization was set off at discharge. Consequently, the device did not optimize atrioventricular and interventricular delays (programming at discharge: 125 ms for the atrioventricular delay and 0 ms for the interventriculardelay). Our patient was treated with an anti-arrhythmic drug. Five months after implantation, his clinical status remained impaired (left ventricular ejection fraction = 30 %). The SonR signal amplitude had also decreased from 0.52 g to 0.29 g. Nevertheless, because our patient was no longer presenting with atrial fibrillation, the anti-arrhythmic treatment was stopped and the SonR optimization system was activated. After 2 months of automatic cardiac resynchronization therapy with defibrillator optimization, our patient's clinical status had significantly improved (left ventricular ejection fraction = 60 %, New York Heart Association class II) and the SonR signal amplitude had doubled shortly after the first weekly automatic optimization. CONCLUSION: In this non-responding patient, device-based automatic cardiac resynchronization therapy optimization was shown to significantly improve his clinical status.


Assuntos
Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca , Cardiomiopatia Dilatada/terapia , Idoso , Bloqueio de Ramo/fisiopatologia , Cardiomiopatia Dilatada/fisiopatologia , Eletrocardiografia , Hemodinâmica , Humanos , Masculino , Medição de Risco , Resultado do Tratamento
14.
J Interv Card Electrophysiol ; 39(2): 153-9, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24293175

RESUMO

PURPOSE: In spite of technological breakthroughs, the choice of a suitable location for the coronary sinus (CS) lead in biventricular implants is still mostly empiric. The aim of this study was to investigate the utility of a radiological index-the distance between the right ventricular (RV) and CS lead tips on fluoroscopic recordings, measured by means of a new method-as a tool for selecting the most profitable left ventricular (LV) lead position. METHODS: Forty-nine consecutive patients (36 male, 13female; mean age 63 ± 19 year), in whom the LV electrode was implanted in a lateral/postero-lateral position in the CS, were evaluated immediately after implantation. The fluoroscopic distances between the RV and LV lead tips were calculated off-line in antero-posterior (2DAP) and latero-lateral (2DLL) projections by means of integrated software. RESULTS: On 1-year follow-up evaluation, 53 % patients were classed as responders (R) (>15 % reduction in LV end-systolic volume) and 47 % as non-responders (NR). On receiver-operating curve analysis, 2DAP and 2DLL showed cut-off values of 81 mm and 51 mm, respectively. In discriminating between R and NR, 2DAP >81 mm displayed 95 % specificity and 74 % sensitivity, while 2DLL >51 mm displayed 74 % specificity and 92 % sensitivity. On multivariate analysis, the cut-off values of 2DAP and 2DLL were significantly predictive of R to CRT. CONCLUSIONS: In our single-center prospective experience, RV-LV interlead distance measured by means of a novel method on fluorographic recordings correlated with CRT response. The use of this method as an intra-operative guide to identifying suitable lead placement in the CS needs evaluating on-line and on a large scale.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Fluoroscopia/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/terapia , Pontos de Referência Anatômicos/diagnóstico por imagem , Feminino , Marcadores Fiduciais , Insuficiência Cardíaca/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia
15.
Hematol J ; 4(5): 346-50, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14502260

RESUMO

BACKGROUND: Cytotoxic regimens used in induction treatments for acute myeloid leukemia (AML) almost always include standard or high-dose cytarabine (Ara-C). During or soon after induction therapy, leukemic patients frequently develop gastroenteric complications, characterized by abdominal pain and diarrhea. The association of these symptoms with fever and melena is typical of necrotizing enterocolitis (NE), a life-threatening condition that can be documented by ultrasound abdominal scan. PATIENTS AND METHODS: We analyzed retrospectively the clinical course of 169 adult patients with AML treated by standard dose Ara-C-containing induction regimens, either by continuous venous infusion (group 1) or subcutaneous injection (group 2). Ultrasonography was employed as early diagnostic tool in a majority of patients with gastroenteric complications. Bowel wall thickening was accurately measured and used to confirm the diagnosis of necrotizing enterocolitis. RESULTS: In the first group of 115 patients (median age, 51 years), gastroenteric complications were observed in 55 patients (48%), and 10 patients (9%) received diagnosis of NE, which was fatal in four. Patients with NE had a median age older than that of patients without gastroenteric symptoms, and a more prolonged neutropenia. In the second group of 54 patients (median age, 60 years), gastroenteric events were observed in 14 patients (26%), and no case of NE was recorded. CONCLUSIONS: This retrospective analysis shows that NE is a serious complication occurring mainly in patients treated by Ara-C administered as continuous i.v. infusion.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/toxicidade , Citarabina/administração & dosagem , Citarabina/toxicidade , Enteropatias/induzido quimicamente , Leucemia Mieloide/tratamento farmacológico , Doença Aguda , Adolescente , Adulto , Idoso , Protocolos de Quimioterapia Combinada Antineoplásica/administração & dosagem , Avaliação de Medicamentos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Enterocolite Necrosante/induzido quimicamente , Enterocolite Necrosante/diagnóstico , Feminino , Humanos , Infusões Parenterais , Injeções Subcutâneas , Leucemia Mieloide/complicações , Masculino , Pessoa de Meia-Idade , Neutropenia/induzido quimicamente , Indução de Remissão , Estudos Retrospectivos , Trombocitopenia/induzido quimicamente
16.
Haematologica ; 87(11): 1225-7, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12414355

RESUMO

Alternative therapeutic approaches with low dose chemotherapy and differentiative-maturative treatment by growth factors are under consideration for elderly patients with acute leukemia. Two patients with AML-M6 with maturation, one refractory to standard chemotherapy and the other ineligible for cytoxic treatment, obtained complete remission from leukemia using high dose recombinant erythropoietin and granulocyte colony-stimulating factor.


Assuntos
Eritropoetina/administração & dosagem , Fator Estimulador de Colônias de Granulócitos/administração & dosagem , Leucemia Eritroblástica Aguda/tratamento farmacológico , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Protocolos de Quimioterapia Combinada Antineoplásica/administração & dosagem , Evolução Fatal , Humanos , Masculino , Indução de Remissão/métodos
SELEÇÃO DE REFERÊNCIAS